 |
|
. |
|
|
 |
|
VCL-MX
Version
6, Upto 80 E1 Voice and
Data Multiplexer -
Ordering Information |
Description
VCL-MX Version 6 - E1 Multiplexer may be used for inter-connecting legacy
networks, provisioning and managing bandwidth on a E1 channelized level as
well as 64Kbps, DS-0 time-slot level and as a digital-access cross-connect
equipment. Due to the changing traffic patterns, there is a need to
support multiple services from the same equipment like integrated data
transport, better network management etc. This necessitated evolution to
next generation E1 Multiplexer. Redundant power supply options make it an
ideal solution for network service providers seeking to integrate and
provide legacy and the next generation services from a single platform.
Next generation E1 Multiplexer has emerged as one of the most economical
and technologically viable solutions for transmitting both over carrier
networks. This technology offers savings on investments/ power and space
to service providers.
Valiant provides efficient solutions in this field using the E1
Multiplexer series products. E1 Multiplexer provides a full range of
solutions in this evolving field of next generation telecom solutions. E1
Multiplexer family provides the unique advantage of carrying both data and
voice over PDH. In addition to being affordable, these products have
built-in modularity, which allow easy upgradeability. This upgradeability
feature allows the customer to evolve in a “build-as-you-grow” concept.
VCL-MX E1 Core System (Common Equipment)
|
|
|
|
S.
No. |
Part
# |
Product
Description |
|
1 |
VCL-MX-1500 |
Control Card with central
processor, cross-connect and system control - may be used in a 1+1
redundant Configuration. Note: Please order 2 numbers for 1+1
redundancy. |
|
2 |
VCL-MX-1490-OAM |
OAM
Card: Management Card for connecting the multiplexer to be managed in a
LAN - allows the USER to assign a unique IP address to each multiplexer
connected in a LAN to be managed from a single point/Telnet |
|
3 |
VCL-MX-1506 |
19" Shelf 6U High (Sub-rack)
with Connectorized Backplane |
|
4 |
VCL-MX-1510 |
(-) 48VDC Input Power Supply
Card - may be used in a 1+1 redundant configuration. Note: Please order
2 numbers for 1+1 redundancy. |
|
5 |
Manual |
Documentation User Manual &
System Software Disks |
|
6 |
Installation Kit |
VCL-MX
Version-6 Installation Kit, includes: RS232 and USB Serial Management
Cables, Ethernet Management Cable, Hardware Set, Power Cables |
VCL-MX, User Configurable Interfaces
|
S.
No. |
Part
# |
Product
Description |
|
1 |
VCL-MX-1530-8 |
8 Port VF, CO (FXO)
Line Interface Card:, 64Kbps/Sec. VF Channels per Central Office Line
Card |
|
2 |
VCL-MX-1530-16 |
16 Port VF, CO (FXO)
Line Interface Card:, 64Kbps/Sec. VF Channels per Central Office Line
Card |
|
3 |
VCL-MX-1525-FXS-8 |
8 Port VF, RT (FXS)
Line Interface Card:, 64Kbps/Sec. VF Channels per Remote Terminal Line
Card |
|
4 |
VCL-MX-1525-FXS-16 |
16 Port VF, RT (FXS)
Line Interface Card:, 64Kbps/Sec. VF Channels per Remote Terminal Line
Card |
|
5 |
VCL-MX-1525-HTL-8 |
8 Port VF, Hot-Line (FXS-Ring-Down)
Interface Card, 64Kbps/Sec. Hot-Line Channels per Card |
|
6 |
VCL-MX-1525-HTL-16 |
16 Port VF, Hot-Line (FXS-Ring-Down)
Interface Card, 64Kbps/Sec. Hot-Line Channels per Card |
|
7 |
VCL-MX-1535-4 |
4 E&M Card - 2 Wire/4
Wire E&M Trunk Interface Card, 64Kbps/Sec. E&M Trunk Interface Card |
|
8 |
VCL-MX-1535-8 |
8 E&M Card - 2 Wire/4
Wire E&M Trunk Interface Card, 64Kbps/Sec. E&M Trunk Interface Card |
|
9 |
VCL-MX-1559-4 |
4 Port RS232 (V.24/V.28
line drivers) DCE Asynchronous Data Interface Card:
50bps to 19.2Kbps. |
|
10 |
VCL-MX-1559-8 |
8 Port RS232 (V.24/V.28
line drivers) DCE Asynchronous Data Interface Card:
50bps to 19.2Kbps. |
|
11 |
VCL-MX-1560-4 |
4 Port G.703, 64Kbps
Co-Directional Data Interface Card |
|
12 |
VCL-MX-1560-8 |
8 Port G.703, 64Kbps
Co-Directional Data Interface Card |
|
13 |
VCL-MX-1547-8 |
8 Port Analog I/O Card.
Accepts/Extends X* analog (dry relay contact) I/O per 64Kbps time-slot,
a total of X* analog (dry relay contact) I/Os per Interface Card |
|
14 |
VCL-MX-1595-ELE |
4 Port 10/100BaseT
Ethernet Electrical card . User configurable from 64Kbps to 16Mbps. User
Selectable Data Transfer Rate (Max. bandwidth per card 16Mbps.) |
|
15 |
VCL-MX-1551-20KM |
8 E1 plus 100Mbps
Ethernet fiber optical transport interface card. (1+1) SFP 1310nm upto
20Km, 8 E1, Optical Interface + 1 Ethernet 100Mbps |
|
16 |
VCL-MX-1551-40KM |
8 E1 plus 100Mbps
Ethernet fiber optical transport interface card (1+1) SFP 1310nm upto
40Km, 8 E1, Optical Interface + 1 Ethernet 100Mbps |
|
17 |
VCL-MX-1551-80KM |
8 E1 plus 100Mbps
Ethernet fiber optical transport interface card. (1+1) SFP 1310nm upto
80Km, 8 E1, Optical Interface + 1 Ethernet 100Mbps |
|
18 |
VCL-MX-1551-120KM |
8 E1 plus 100Mbps
Ethernet fiber optical transport interface card. (1+1) SFP 1310nm upto
120Km, 8 E1, Optical Interface + 1 Ethernet 100Mbps |
|
19 |
VCL-MX-1540 |
Ring Generator Card,
Central Office Ring Generator Card 1 per system. (75 volts RMS). To be
ordered for any chassis with FXS card(s) - one card per chassis. |
|
20 |
VCL-MX-1520 |
8 E1 Interfaces with
full capability to cross connect at DS-0, 64Kbps time-slot level as well
as to inter-connect to voice and digital data services between 80
incoming E1 Ports (i.e. 80 separate E1 links)
Note: Please order 2 numbers for 1+1 redundancy. |
|
21 |
VCL-MX-1545 |
4 Port
RS232/RS485/RS422/V.35/V.36 - User Selectable Data Interface Card: 8
Port, 50bps to 19.2Kbps RS232/RS485/RS422 Asynchronous/Synchronous Data
Interface Card. Max 09 cards per each system. |
|
22 |
VCL-MX-1558 |
4 Port Universal Data
Interface Card - User Configurable: V.35/V.36/RS422/V.11/RS530/X.21, DTE/DCE,
"N" x 64Kbps Synchronous Data Interface. User Selectable Data Rate of
"N" (1 thru 31) - DCE or DTE (User Configurable DCE or DTE modes). |
|
23 |
VCL-MX-TP-1553 |
8 Command
Teleprotection Terminal (8 Nos. Tx & Rx independent command inputs &
outputs for providing interconnection with Relay of DPS). |
|
24 |
VCL-MX-1552 |
4 Port Optical
Interface directly for protection relay for distance teleprotection
interface card complying with IEEE C37.94. |
Optional and Accessories
|
S.
No. |
Part
# |
Product
Description |
|
1 |
VCL-MX-01048 19-RK |
Power Supply (External)
AC to DC Converter External Converter Universal AC Input [93VAC-276VAC,
47Hz-63Hz] to DC Output [(-) 48VDC] |
|
2 |
Cables |
Connectorized Cables
for FXS/FXO Cards (3 meters, DB25 to Open) - 2 cables per 16 port card
and 1 cables per 8 port card |
|
3 |
Cables |
E&M Connectorized
Cables (3 meters, DB25 to Open) - 2 cables per 4 port card |
|
4 |
Cables |
Connectorized Cables
for RS232 Async. Cards (3 meters, DB25 to Open OR DB25 to DB25). Please
clarify. - 2 cables per 8 port card |
|
5 |
Cables |
Connectorized Cables
for G.703 Cards (3 meters, DB25 to Open OR DB25 to RJ-45). Please
clarify. - 2 cables per 8 port card |
|
6 |
Cables |
Connectorized Cables
for AIO Cards (3 meters, DB25 to Open) - 4 cables per 16 port card |
|
7 |
Cables |
Ethernet Connectorized Cables
(3 meters, DB25 to RJ-45) - 4 cables per 4 port card |
|
8 |
Cables |
V.35 (M34 - Winchester) - "n"
x 64Kbps Connectorized Cable (3 meters, DB25 to Winchester) - 4 cables
per 4 port card |
|
9 |
Cables |
V.36/X.21/RS530/V.11 -
"n" x 64Kbps Connectorized Cable (3 meters, DB25 to DB25) - 4 cables per
4 port card |
|
10 |
Cables |
E1 Interface -Connectorized
Cables (3 meters, DB25 to Open) - 2 cables per 8 port card |
|
11 |
VCL-1505-TER-DB37F-RJ45F-16PP |
16 x E1, DB-37
[2xDB37F] to RJ-45 [16xRJ45F] 120OhmsTermination Panel [1x1505T01]. 19"
Metal case 1U High Rack Mount Version |
|
12 |
Cables |
E1 Interface - DB-37(M)
to 2 x DB-25(M) Cable - 1 Cable per E1 card |
|
13 |
Blank-Plate 6U |
6U high blank plates to
cover un-used slots |
|
14 |
Blank-Plate 3U |
3U high blank plates to
cover un-used slots |
|
15 |
VCL-1513/1514-TER-DB37F-BNCF-8PP |
16 x E1, DB-37
[2xDB37F] to BNC [16xBNCF] 75Ohms Termination Panel [1x1513T01 and
1514T00]. 19" Metal case 1U High Rack Mount Version |
Related Links
Other Related Links
|
 |
|
. |
|
|
|
. |
|
|